Golden Elephant No. 1 Corn

"Jinxiang No. 1" was selected by Gansu Golden Elephant Co., Ltd. using its self-cultivated maize inbred lines "Jinxiang 4C" and "Gongxiang 55", and was approved by the Gansu Provincial Crop Variety Approval Committee in 2003. Characteristic characteristics Springtime sowing 150 days, summer sowing 105 to 110 days, is a late-maturing varieties, seedlings top soil ability, emergence of neat, strong growth potential. Plant type compact, delicate plants, broad leaves, dark green, plant height 305 cm, ear height 142.9 cm, stem diameter 3.98 cm, ear length 22.4 ~ 24.5 cm, ear cylindrical, grain dentate, orange, Cob white, seed production rate of 86.4%, 1000 grain weight 390 ~ 435 g, performance of high resistance to head smut, spot disease, red leaf disease, drought tolerance, lodging resistance, maximum yield per mu in 66 experimental demonstration sites in 13 provinces Up to 1187 kilograms, with an average yield of 878.5 kilograms, an increase of 161.91 kilograms compared with the single crop on the second crop, an increase of 22.4%, an increase of 12.6% from the Agricultural University, and an increase of more than 10% over the Yuyu 22 production. Tested by the Testing Center of Gansu Academy of Agricultural Sciences, the grain contained 11% of crude protein (dry basis), 70.65% of starch (dry basis), 5.05% of fat (dry basis), and 0.32% of lysine (dry basis). Feed and use corn varieties. Appropriate range: Gansu Hexi area, Tianshui, Linxia, ​​Longnan and Shandong, Henan, Ningxia and other places in spring or summer sowing, can also be interplanted with wheat and other crops or single species.

Trauma Cannulated Screw

Cannulated screw is a common internal fixation device in orthopedic surgery.

Working process

During the operation, the Kirschner wire with the hole matching the hollow screw is first drilled into the bone of the fracture site, and then the hollow screw is screwed into the fracture site through the guidance of the Kirschner wire. Finally, the Kirschner wire is pulled out to complete the fixation of the fracture site. In many cases of fracture of the neck and femur, the healing cycle is long, and it usually takes about 30 months to remove the cannulated screws. At this point, the bone and the surface of the cannulated nail are closely connected and firmly connected in the nail path, which leads to defects easily generated by conventional nail removal methods, causing secondary injury at the fracture healing site and causing pain to the patient. Percutaneous cannulated screw internal fixation for femoral neck fractures has the advantages of small trauma, good healing, low rate of femoral head necrosis, and good stability.

compression fracture,Cannulated Screws,surgery screws,Orthopedic Screw

Jiangsu Aomed Ortho Medical Technology Co.,Ltd , https://www.aomedortho.com