Medical Equipment High Grade Infant Radiant Warmer (HNT-2000)

Model NO.: HNT-2000
Temperature Control Mode: Pre-Heat\Auto and Manual
Temperature Control Range: 25°c~37°c
Temperature Override Mode to: 38°c
Radiant Box Horizon Angle Adjust Range: 0~±90° Step-Less
Mattress Tray Size: 68cm×56cm
Mattress Tilt Adjust Range: 0~±10° Step-Less
Mattress Tray Max. Load: 10 Kg
RS-232 Connector: Yes
Mattress to Radiant Box: 81 Cm
Packing Size: 110 ×90 ×110 Cm, 85 Kg
Trademark: Healicom
Transport Package: Wooden Case
Specification: ISO
Origin: China
HS Code: 90189090
Model NO.: HNT-2000
Temperature Control Mode: Pre-Heat\Auto and Manual
Temperature Control Range: 25°c~37°c
Temperature Override Mode to: 38°c
Radiant Box Horizon Angle Adjust Range: 0~±90° Step-Less
Mattress Tray Size: 68cm×56cm
Mattress Tilt Adjust Range: 0~±10° Step-Less
Mattress Tray Max. Load: 10 Kg
RS-232 Connector: Yes
Mattress to Radiant Box: 81 Cm
Packing Size: 110 ×90 ×110 Cm, 85 Kg
Trademark: Healicom
Transport Package: Wooden Case
Specification: ISO
Origin: China
HS Code: 90189090
Standard composition
1. Temperature Control Mode: pre-heating control, servo control & manual control;
2. Instant Parameter Display: set temp, skin temp, heat power rate;
3. Built-in APGAR Timer and >37°C preset function
4. Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
5. Tilting Bed with Rotary Radiant Head;
6. X-ray Cassette Tray under infant bed, examination light of high illuminance;
7. Use anti-blast quartz infrared tube as radiant heating source.
 
Technical specification
Power AC 110 / 220 V, 50Hz / 60Hz
Input Power ≤1000VA
Temperature control range and relative specification Control mode Pre-warm mode, manual mode, baby mode
Temperature control range 25°C~37°C, for set temperature ≤37°C
37°C~38°C, for set temperature >37°C
Skin temperature sensor measure range 20°C~42°C
Deviation between sensor measure temperature and control temperature ≤0.5°C
Skin Sensor Precision ≤0.3°C
Bed surface temperature Uniformity ≤1°C
Temperature Rise Time ≤45min
Bed tiltable continues adjustable in ±10°
Alarm Sensor failure alarm Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarm Alarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C, cut off power.
Deviation alarm After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.
Power failure alarm Alarm with audible and visual when power failure
APGAR time Alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes.
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.) Operate temperature range 18°C~30°C
Store temperature range -20°C~+55°C
Environment Humidity Operate humidity range 30%RH~75%RH
Store humidity range ≤93%RH
Atmospheric pressure Transport and Store atmospheric pressure range 500hPa~1060hPa
Operate atmospheric pressure range 700hPa~1060hPa
Stream velocity Ambit environment stream velocity ≤0.3m/s
 
 
Specifications HNT-1000 HNT-2000 HNT-2000B
Operational condition:  
Environment temperature +18°C~+30°C +18°C~+30°C +18°C~+30°C
Environment relative humidity 30%~75% 30%~75% 30%~75%
Environment air velocity of flow <0.3m/s <0.3m/s <0.3m/s
Power requirement ≤1000VA ≤1000VA ≤1000VA
Temperature control mode Auto Pre-heat\auto and manual Pre-heat\auto and manual
Temperature Control Range 25°C~37°C 25°C~37°C 25°C~37°C
Temperature override mode to ----- 38°C 38°C
Temperature sensor accuracy ≤0.3°C ≤0.3°C ≤0.3°C
Mattress temperature uniformity ≤2.0°C ≤2.0°C ≤2.0°C
Temperature rise time ≤45 min ≤45 min ≤45 min
Heat output indicate 0~100% 0~100% 0~100%
Radiant box horizon angle adjust range 0~±90°step-less 0~±90° step-less 0~±90° step-less
Mattress Tray Size 68cm×56cm 68cm×56cm 68cm×56cm
Mattress tilt adjust range 0~±10° step-less 0~±10° step-less 0~±10° step-less
Mattress tray Max. load 10 kg 10 kg 10 kg
Transfusion pole Max. load 2 kg 2 kg 2 kg
Shelf Max. load 2 kg 2 kg 2 kg
X-ray Yes Yes Yes
RS-232 Connector ---- Yes Yes
Mattress to Radiant box 81 cm 81 cm 81 cm
Heater infrared wavelength 1~3 μm 1~3 μm 1~3 μm
APGAR Timer ----- Yes Yes
Alarms  
Power failure alarm Yes Yes Yes
Sensor failure alarm Yes Yes Yes
Temperature deviation alarm ±1.0°C ±1.0°C ±1.0°C
Over temperature alarm ≤38.0°C ≤38.0°C\≤39.0°C ≤38.0°C\≤39.0°C
System failure alarm ----- Yes Yes
Low-pressure suction ------ ----- Yes
Pressure adjust range ------ ---- 0~22Kp(0~165mmHg)
Operating noise ------ ---- ≤55dB
White Phototherapy light ------ ------ 1 set
7L Oxygen cylinder (with oxygen manometer & oxygen flow meter) ------ ------ 2 sets
Neonate resuscitation bag ------ ------ 1 set
Packing size 110×90×110 cm 110  ×90 ×110 cm 110 ×90 ×110 cm
Net weight 85 kg 85 kg 95 kg
Gross Weight 115 kg 115 kg 125 kg

  Standard composition
1. Temperature Control Mode: pre-heating control, servo control & manual control;
2. Instant Parameter Display: set temp, skin temp, heat power rate;
3. Built-in APGAR Timer and >37°C preset function
4. Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
5. Tilting Bed with Rotary Radiant Head;
6. X-ray Cassette Tray under infant bed, examination light of high illuminance;
7. Use anti-blast quartz infrared tube as radiant heating source.
 
Technical specification
Power AC 110 / 220 V, 50Hz / 60Hz
Input Power ≤1000VA
Temperature control range and relative specification Control mode Pre-warm mode, manual mode, baby mode
Temperature control range 25°C~37°C, for set temperature ≤37°C
37°C~38°C, for set temperature >37°C
Skin temperature sensor measure range 20°C~42°C
Deviation between sensor measure temperature and control temperature ≤0.5°C
Skin Sensor Precision ≤0.3°C
Bed surface temperature Uniformity ≤1°C
Temperature Rise Time ≤45min
Bed tiltable continues adjustable in ±10°
Alarm Sensor failure alarm Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarm Alarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C, cut off power.
Deviation alarm After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.
Power failure alarm Alarm with audible and visual when power failure
APGAR time Alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes.
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.) Operate temperature range 18°C~30°C
Store temperature range -20°C~+55°C
Environment Humidity Operate humidity range 30%RH~75%RH
Store humidity range ≤93%RH
Atmospheric pressure Transport and Store atmospheric pressure range 500hPa~1060hPa
Operate atmospheric pressure range 700hPa~1060hPa
Stream velocity Ambit environment stream velocity ≤0.3m/s
 
 
Specifications HNT-1000 HNT-2000 HNT-2000B
Operational condition:  
Environment temperature +18°C~+30°C +18°C~+30°C +18°C~+30°C
Environment relative humidity 30%~75% 30%~75% 30%~75%
Environment air velocity of flow <0.3m/s <0.3m/s <0.3m/s
Power requirement ≤1000VA ≤1000VA ≤1000VA
Temperature control mode Auto Pre-heat\auto and manual Pre-heat\auto and manual
Temperature Control Range 25°C~37°C 25°C~37°C 25°C~37°C
Temperature override mode to ----- 38°C 38°C
Temperature sensor accuracy ≤0.3°C ≤0.3°C ≤0.3°C
Mattress temperature uniformity ≤2.0°C ≤2.0°C ≤2.0°C
Temperature rise time ≤45 min ≤45 min ≤45 min
Heat output indicate 0~100% 0~100% 0~100%
Radiant box horizon angle adjust range 0~±90°step-less 0~±90° step-less 0~±90° step-less
Mattress Tray Size 68cm×56cm 68cm×56cm 68cm×56cm
Mattress tilt adjust range 0~±10° step-less 0~±10° step-less 0~±10° step-less
Mattress tray Max. load 10 kg 10 kg 10 kg
Transfusion pole Max. load 2 kg 2 kg 2 kg
Shelf Max. load 2 kg 2 kg 2 kg
X-ray Yes Yes Yes
RS-232 Connector ---- Yes Yes
Mattress to Radiant box 81 cm 81 cm 81 cm
Heater infrared wavelength 1~3 μm 1~3 μm 1~3 μm
APGAR Timer ----- Yes Yes
Alarms  
Power failure alarm Yes Yes Yes
Sensor failure alarm Yes Yes Yes
Temperature deviation alarm ±1.0°C ±1.0°C ±1.0°C
Over temperature alarm ≤38.0°C ≤38.0°C\≤39.0°C ≤38.0°C\≤39.0°C
System failure alarm ----- Yes Yes
Low-pressure suction ------ ----- Yes
Pressure adjust range ------ ---- 0~22Kp(0~165mmHg)
Operating noise ------ ---- ≤55dB
White Phototherapy light ------ ------ 1 set
7L Oxygen cylinder (with oxygen manometer & oxygen flow meter) ------ ------ 2 sets
Neonate resuscitation bag ------ ------ 1 set
Packing size 110×90×110 cm 110  ×90 ×110 cm 110 ×90 ×110 cm
Net weight 85 kg 85 kg 95 kg
Gross Weight 115 kg 115 kg 125 kg

 

Pheromone

Pheromone is a collective name for compounds that play a role in chemical communication between organisms, and which is the chemical molecular language of insect communication. Including sex pheromone, collection pheromone, alert pheromone, tracking pheromone, altruin, altruin, synergistic pheromone, evacuation pheromone. Pheromones are chemical substances that interact with each other and can affect each other's behavior, habits, and even development and physiological activities. Pheromone is produced by the glands in the body and is directly discharged to the outside. The pheromone is transmitted to other individuals by means of air, water and other conductive media. Pheromones are found in lower animals and higher mammals. Because the pheromone is transmitted by the external environment, it is also called pheromone. Chemical substances that interact between different species are called interspecies pheromones or heteropheres.

Insect pheromones are compounds used by insects to represent various information such as aggregation, foraging, mating, and alerting. They are the chemical molecular language of insect communication. At present, the basic control measures for pests in agricultural production mainly rely on chemical pesticides, but the long-term uncontrolled use of chemical pesticides has brought many side effects. The first is the emergence of pest resistance, which causes the use of drugs and drug concentrations to increase, the cost increases year by year, and the prevention and control of increasingly difficult; the second is to disrupt the ecological balance, while controlling a large number of natural enemies were killed, causing the pupae of secondary pests; Third, it pollutes the environment. A large amount of pesticides remain in crops, soils, rivers, lakes, and seas, and they are enriched in the human body through the form of food chain, causing another harm to humanity. Therefore, relevant research departments in many countries are currently working hard to explore and study new approaches and technologies for pest control. These studies include: the development of new, efficient, environmentally friendly, low-toxic, low-residue chemical pesticides; natural enemy insects and microorganisms The use of pesticides; insect sterilization technology and the application of insect hormones; among them, the research on the use of insect hormones, especially insect sex pheromones for pest control, is receiving increasing attention and attention.

Research on insect pheromone has been developing rapidly. Since the first insect pheromone Bombykol, has been isolated and identified, more than 2,000 insect pheromones and their analogs have been identified and synthesized worldwide, of which more than 100 insect pheromone To achieve commercial production, the production and research of Lepidoptera sex pheromones is the most extensive and comprehensive.

Insect communication, Including Sex pheromone, Collection pheromone,Alert pheromone, Tracking pheromone

Taizhou Volsen Chemical Co., Ltd. , https://www.volsenchem.com